Product Details:
| Minimum Order Quantity | 100 Kg |
| Packaging Size | 20 kg |
| Color | Off White |
| Paint Base Type | Water based |
| Form | Paste |
| Usage/Application | Cable Coating |
| Packaging Type | Can |
| Brand | RUDRA PAINT |
| Coverage | 3 Kg / Sq M |
| Shelf Life | 1 Year |
| Storage | Dry Place |
| Physical Form | Liquid |
| Bulk Density | 2.1 |
| Ph Value | 7.6 |
| Limiting Oxygen Index | Over 70 |
| Touch Dry | 2 Hours |
| Hard Dry | 24 Hours |
| Complete Curing | 7 Days |
Additional Information:
Product Details:
| Minimum Order Quantity | 100 Litre |
| Packaging Size | 20 KG |
| Color | Off White |
| Packaging Type | Bucket |
| Paint Base Type | Water based |
| Application Temperature Range | RUDRA PAINT |
| Payment Mode | ONLINE |
| Finish | Matt |
| Is Sealer Required | Yes |
| Shelf Life | 9 Month |
| Is it Fire Resistant | Yes |
| Country of Origin | Made in India |
| Specific Gravity | 1.1 |
| PH Value | 7.6 |
| Solid Contents: | 70% |
| Limiting Oxygen Index | Over 70 |
| Recommended D.F.T | 2mm |
| Coverage | 3 Kg Per Sq M |
| Touch Dry | 2 Hrs |
| Hard Dry | 24 Hrs |
| Fire Survival IEC-331 | Meets The Requirement For The Limited Period Of 20 Minute |
| Usage/Application | For Cables |
Additional Information:
Product Details:
| Packaging Size | 20 kg |
| Brand | RUDRA PAINT |
| Finish | Matt |
| Color | grey |
| Form | Liquid |
| Usage/Application | Floor Separation |
| Packaging Type | bag |
| Paint Base Type | Water Based |
| Specific Gravity | 1.1 |
| Shelf Life | 1 Year |
| Ph Value | 7.6 |
| Solid Contents | 70% |
| Limiting Oxygen Index | Over 70 |
| Touch Dry | 2 Hrs |
| Hard Dry | 24 Hrs |
| Complete Curing | 7 Days |
Floor separation fire resistance coatings are specialized coatings applied to building structures to enhance fire resistance and prevent the spread of fire through floor assemblies. These coatings are designed to delay the failure of structural elements during a fire, allowing occupants more time to evacuate and firefighters more time to control the situation. Here's some information about floor separation fire resistance coatings:
Fire Protection Mechanism: These coatings work to delay the failure of structural elements by providing a layer of fire-resistant material. This can include intumescent materials that expand when exposed to heat, forming a protective insulating layer that slows down the transfer of heat to the structure.
Application Areas: Floor separation fire resistance coatings are typically applied to structural elements such as steel and concrete that are part of floor assemblies. This includes beams, columns, and other components that support the structure.
Fire Resistance Ratings: The effectiveness of these coatings is often measured in terms of fire resistance ratings, indicating the duration for which they can withstand a standard fire test. Common ratings include 1 hour, 2 hours, 3 hours, and so on.
Types of Coatings:
Compatibility with Other Building Materials: Floor separation fire resistance coatings should be compatible with other building materials, including insulation and finishes. Compatibility is important to maintain the overall integrity of the fire protection system.
Thickness Requirements: Achieving the required fire resistance rating often involves applying the coating at a specific thickness. The manufacturer's guidelines and industry standards should be followed to ensure proper application and coverage.
Application Methods: Coatings can be applied using various methods, including spraying, brushing, or troweling, depending on the specific product and application requirements.
Environmental Considerations: Considerations such as volatile organic compound (VOC) content and environmental impact may be important when selecting coatings. Water-based formulations or low-VOC options are available for those seeking environmentally friendly alternatives.
Testing and Certification: Floor separation fire resistance coatings may undergo testing and certification by relevant authorities to ensure they meet fire safety standards. Look for products with recognized certifications.
Inspection and Maintenance: Regular inspection and maintenance are crucial to ensure that the fire resistance coatings remain intact and effective. Any damage or deterioration should be addressed promptly to maintain the structural fire protection.
Regulatory Compliance: Ensure that the chosen floor separation fire resistance coating complies with local building codes and regulations. Compliance with fire safety standards is critical for the overall safety of the structure.
Before selecting and applying floor separation fire resistance coatings, it's important to consult with coating specialists, follow the manufacturer's guidelines, and adhere to industry standards and local regulations. Proper application and maintenance are essential for ensuring the effectiveness of fire protection in the event of a fire.
Additional Information:
Product Details:
| Minimum Order Quantity | 20 Litre |
| Unit Pack Size | Bucket of 20 Litre |
| Packaging Size | 20L |
| Usage/Application | Industrial Use |
| Packaging Type | 20 LTR |
| Color | ANNY |
Protective coatings encompass a wide range of materials applied to surfaces for the purpose of safeguarding them against various environmental, chemical, or physical exposures. These coatings are designed to enhance the durability, performance, and longevity of substrates. Here's some general information about protective coatings:
Types of Protective Coatings:
Materials Used:
Surface Preparation:
Application Methods:
Durability and Longevity:
Adhesion:
Environmental Considerations:
Regulatory Compliance:
Testing and Certification:
Application Areas:
Maintenance:
Additional Information:
Product Details:
| Packaging Size | 20L |
| Usage/Application | Industrial Use |
| Color | Grey |
| Packaging Type | Drum |
| Shelf Life | 24 Months |
Anti Magnetic Coating — a specialized protective layer designed to shield sensitive equipment from magnetic interference.
Reduces the impact of external magnetic fields on devices
Enhances accuracy and stability of precision instruments
Suitable for scientific, industrial, and electronic applications
Provides a smooth, durable, and long-lasting finish
Can be applied to metals, machinery, and enclosures
Resistant to wear, moisture, and environmental damage
Helps extend the lifespan of protected equipment
Easy to apply using spray, brush, or dip methods
Product Details:
| Minimum Order Quantity | 20 Piece |
| Material | GOVERMENT LAB TASTED CERTIFICATE |
| Country of Origin | Made in India |
Fire seal mortar, also known as firestop mortar or fire barrier mortar, is a type of fire-resistant material used to seal openings and joints in walls, floors, and ceilings to prevent the spread of fire, smoke, and toxic gases. Here is detailed information about fire seal mortar:
CompositionFire seal mortar typically consists of the following components:
Fire seal mortar is used in various applications, including:
Key properties of fire seal mortar include:
The installation process typically involves the following steps:
Fire seal mortar must comply with various building codes and standards, which may include:
Regular inspections and maintenance are crucial to ensure the effectiveness of fire seal mortar. Over time, it may be necessary to repair or replace mortar that has been damaged or degraded.
Additional Information:
Product Details:
| Coating type | Fire retardant |