Fire Protective Coatings

Pioneers in the industry, we offer cable fire resistance coating, fire resistant cable coating, floor separation fire resistance coating, protective coatings, anti magnetic coating and rudra fire barrier from India.

Cable Fire Resistance Coating

Cable Fire Resistance Coating
  • Cable Fire Resistance Coating
  • Cable Fire Resistance Coating
  • Cable Fire Resistance Coating
  • Cable Fire Resistance Coating
  • Cable Fire Resistance Coating
Get Best Quote
Approx. Price: Rs 550 / KgGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity100 Kg
Packaging Size20 kg
ColorOff White
Paint Base TypeWater based
FormPaste
Usage/ApplicationCable Coating
Packaging TypeCan
BrandRUDRA PAINT
Coverage3 Kg / Sq M
Shelf Life1 Year
StorageDry Place
Physical FormLiquid
Bulk Density2.1
Ph Value7.6
Limiting Oxygen IndexOver 70
Touch Dry2 Hours
Hard Dry24 Hours
Complete Curing7 Days

SURFACE PREPARATION Remove grease, oil, coal dust and other contaminants from the cable trays and clean the tray thoroughly before applying REC - 106 HEALTH & SAFETY All work involving the application and use of this product should be performed in compliance with all relevant National Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you cannot strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during applying and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (i.e. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependent on application methods and work environment. This is a solvent based primer and care should be taken to avoid inhalation of spray mist or vapor as well as contact between the wet paint and exposed skin or eyes. APPLICATION METHOD Stir REC – 106 thoroughly. Add clean water into the paint as required, depending on application method, and stir thoroughly for few minutes. The temperature of the substrate should be minimum 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure correct drying. All equipments used for above should be properly cleaned. Do not allow material to remain in hoses, gun or spray equipment. PAGE 3 Thoroughly flush all equipment with clean water. Clean all equipments immediately after use with water. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Application: By Brush/By Airless Spray Nozzle Orifice: Air less spray 0.58 mm Nozzle Pressure: Airless Spray 1400-1800 p.s.i.
Request
Callback


Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 2 days
  • Packaging Details: 20 kg can
Yes! I am Interested

Fire Resistant Cable Coating

Fire Resistant Cable Coating
  • Fire Resistant Cable Coating
  • Fire Resistant Cable Coating
  • Fire Resistant Cable Coating
  • Fire Resistant Cable Coating
  • Fire Resistant Cable Coating
Get Best Quote
Approx. Price: Rs 550 / LitreGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity100 Litre
Packaging Size20 KG
ColorOff White
Packaging TypeBucket
Paint Base TypeWater based
Application Temperature RangeRUDRA PAINT
Payment ModeONLINE
FinishMatt
Is Sealer RequiredYes
Shelf Life9 Month
Is it Fire ResistantYes
Country of OriginMade in India
Specific Gravity1.1
PH Value7.6
Solid Contents:70%
Limiting Oxygen IndexOver 70
Recommended D.F.T2mm
Coverage3 Kg Per Sq M
Touch Dry2 Hrs
Hard Dry24 Hrs
Fire Survival IEC-331Meets The Requirement For The Limited Period Of 20 Minute
Usage/ApplicationFor Cables

SURFACE PREPARATION Remove grease, oil, coal dust and other contaminants from the cable trays and clean the tray thoroughly before applying REC - 106 HEALTH & SAFETY All work involving the application and use of this product should be performed in compliance with all relevant National Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you cannot strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during applying and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (i.e. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependent on application methods and work environment. This is a solvent based primer and care should be taken to avoid inhalation of spray mist or vapor as well as contact between the wet paint and exposed skin or eyes. APPLICATION METHOD Stir REC – 106 thoroughly. Add clean water into the paint as required, depending on application method, and stir thoroughly for few minutes. The temperature of the substrate should be minimum 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure correct drying. All equipments used for above should be properly cleaned. Do not allow material to remain in hoses, gun or spray equipment. PAGE 3 Thoroughly flush all equipment with clean water. Clean all equipments immediately after use with water. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Application: By Brush/By Airless Spray Nozzle Orifice: Air less spray 0.58 mm Nozzle Pressure: Airless Spray 1400-1800 p.s.i.
Request
Callback


Additional Information:

  • Production Capacity: 1000 KG PER DAY
  • Delivery Time: DEPENDING UPON ORDER
  • Packaging Details: 20 KG
Yes! I am Interested

Floor Separation Fire Resistance Coating

Floor Separation Fire Resistance Coating
  • Floor Separation Fire Resistance Coating
Get Best Quote
Approx. Price: Rs 105 / KgGet Latest Price
Product Brochure

Product Details:

Packaging Size20 kg
BrandRUDRA PAINT
FinishMatt
Colorgrey
FormLiquid
Usage/ApplicationFloor Separation
Packaging Typebag
Paint Base TypeWater Based
Specific Gravity1.1
Shelf Life1 Year
Ph Value7.6
Solid Contents70%
Limiting Oxygen IndexOver 70
Touch Dry2 Hrs
Hard Dry24 Hrs
Complete Curing7 Days

Floor separation fire resistance coatings are specialized coatings applied to building structures to enhance fire resistance and prevent the spread of fire through floor assemblies. These coatings are designed to delay the failure of structural elements during a fire, allowing occupants more time to evacuate and firefighters more time to control the situation. Here's some information about floor separation fire resistance coatings:

  1. Fire Protection Mechanism: These coatings work to delay the failure of structural elements by providing a layer of fire-resistant material. This can include intumescent materials that expand when exposed to heat, forming a protective insulating layer that slows down the transfer of heat to the structure.

  2. Application Areas: Floor separation fire resistance coatings are typically applied to structural elements such as steel and concrete that are part of floor assemblies. This includes beams, columns, and other components that support the structure.

  3. Fire Resistance Ratings: The effectiveness of these coatings is often measured in terms of fire resistance ratings, indicating the duration for which they can withstand a standard fire test. Common ratings include 1 hour, 2 hours, 3 hours, and so on.

  4. Types of Coatings:

    • Intumescent Coatings: These coatings expand when exposed to heat, forming a protective layer. Intumescent coatings are often used for steel structures.
    • Cementitious Coatings: These coatings are based on cement-like materials that provide a layer of fire resistance. They are often used on concrete surfaces.
  5. Compatibility with Other Building Materials: Floor separation fire resistance coatings should be compatible with other building materials, including insulation and finishes. Compatibility is important to maintain the overall integrity of the fire protection system.

  6. Thickness Requirements: Achieving the required fire resistance rating often involves applying the coating at a specific thickness. The manufacturer's guidelines and industry standards should be followed to ensure proper application and coverage.

  7. Application Methods: Coatings can be applied using various methods, including spraying, brushing, or troweling, depending on the specific product and application requirements.

  8. Environmental Considerations: Considerations such as volatile organic compound (VOC) content and environmental impact may be important when selecting coatings. Water-based formulations or low-VOC options are available for those seeking environmentally friendly alternatives.

  9. Testing and Certification: Floor separation fire resistance coatings may undergo testing and certification by relevant authorities to ensure they meet fire safety standards. Look for products with recognized certifications.

  10. Inspection and Maintenance: Regular inspection and maintenance are crucial to ensure that the fire resistance coatings remain intact and effective. Any damage or deterioration should be addressed promptly to maintain the structural fire protection.

  11. Regulatory Compliance: Ensure that the chosen floor separation fire resistance coating complies with local building codes and regulations. Compliance with fire safety standards is critical for the overall safety of the structure.

Before selecting and applying floor separation fire resistance coatings, it's important to consult with coating specialists, follow the manufacturer's guidelines, and adhere to industry standards and local regulations. Proper application and maintenance are essential for ensuring the effectiveness of fire protection in the event of a fire.

Request
Callback


Additional Information:

  • Packaging Details: SURFACE PREPARATION Remove grease, oil, coal dust and other contaminants from the opening area before sealing the cavity with REC – 10 HEALTH & SAFETY All work involving the application and use of this product should be performed in compliance with all relevant National Health, Safety & Environmental standards and regulations. Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read and follow all precautionary notices on the Material Safety Data Sheet and container labels. If you do not fully understand these warnings and instructions or if you cannot strictly comply with them, do not use this product. Proper ventilation and protective measures must be provided during applying and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. Take precautions to avoid skin and eye contact (i.e. gloves, goggles, face masks, barrier creams etc.) Actual safety measures are dependent on application methods and work environment. This is a solvent based primer and care should be taken to avoid inhalation of spray mist or vapor as well as contact between the wet paint and exposed skin or eyes. ADDITIONAL INFORMATION Further information regarding industry standards, terms and abbreviations used in this data sheet contact us.
Yes! I am Interested

Protective Coatings

Protective Coatings
  • Protective Coatings
  • Protective Coatings
  • Protective Coatings
  • Protective Coatings
  • Protective Coatings
Get Best Quote
Approx. Price: Rs 425 / LitreGet Latest Price

Product Details:

Minimum Order Quantity20 Litre
Unit Pack SizeBucket of 20 Litre
Packaging Size20L
Usage/ApplicationIndustrial Use
Packaging Type20 LTR
ColorANNY

Protective coatings encompass a wide range of materials applied to surfaces for the purpose of safeguarding them against various environmental, chemical, or physical exposures. These coatings are designed to enhance the durability, performance, and longevity of substrates. Here's some general information about protective coatings:

  1. Types of Protective Coatings:

    • Corrosion-resistant Coatings: Protect against corrosion on metal surfaces.
    • Fire-retardant Coatings: Reduce flammability and slow down the spread of fire.
    • Weather-resistant Coatings: Shield surfaces from the effects of weather, including UV radiation, rain, and temperature fluctuations.
    • Chemical-resistant Coatings: Provide protection against chemical exposure, preventing damage or degradation.
    • Abrasion-resistant Coatings: Resist wear and tear due to friction, impact, or abrasion.
    • Anti-graffiti Coatings: Facilitate easier removal of graffiti and prevent damage to underlying surfaces.
    • Waterproofing Coatings: Prevent water penetration, protecting against moisture-related damage.
  2. Materials Used:

    • Polymer-based Coatings: Such as epoxies, polyurethanes, and acrylics, offering a combination of adhesion, flexibility, and chemical resistance.
    • Ceramic-based Coatings: Provide high-temperature resistance and durability.
    • Metallic Coatings: Including zinc, aluminum, or galvanized coatings for corrosion protection.
    • Intumescent Coatings: Expand when exposed to heat, forming an insulating layer to protect against fire.
  3. Surface Preparation:

    • Proper surface preparation is crucial for the effectiveness of protective coatings. It may involve cleaning, sanding, or applying primers to ensure good adhesion.
  4. Application Methods:

    • Protective coatings can be applied using various methods, including brushing, rolling, spraying, or dipping. The choice of application method depends on the coating type and the substrate.
  5. Durability and Longevity:

    • The durability of protective coatings depends on factors such as formulation, proper application, and the severity of environmental exposures. Some coatings provide long-lasting protection, reducing the need for frequent maintenance.
  6. Adhesion:

    • Good adhesion to the substrate is essential for the effectiveness of protective coatings. Adhesion can be influenced by surface preparation and the compatibility between the coating and the substrate.
  7. Environmental Considerations:

    • Some coatings may contain volatile organic compounds (VOCs) or other environmentally sensitive materials. Water-based, low-VOC, or environmentally friendly alternatives are available for certain applications.
  8. Regulatory Compliance:

    • Ensure that the chosen protective coating complies with relevant regulations and standards, especially in industries with specific requirements, such as construction, automotive, or aerospace.
  9. Testing and Certification:

    • High-quality protective coatings may undergo testing and certification to ensure they meet industry standards for performance, safety, and environmental impact.
  10. Application Areas:

    • Protective coatings find applications in a wide range of industries, including construction, automotive, marine, aerospace, oil and gas, and infrastructure.
  11. Maintenance:

    • Regular inspection and maintenance may be required to ensure the continued effectiveness of protective coatings, especially in harsh environment
Request
Callback


Additional Information:

  • Item Code: RP-617
  • Production Capacity: 20000 PAR MUNTH
  • Delivery Time: 3 TO 4 DAYS
Yes! I am Interested

Anti Magnetic Coating

Anti Magnetic Coating
  • Anti Magnetic Coating
  • Anti Magnetic Coating
Ask For Price
Product Price :Get Latest Price

Product Details:

Packaging Size20L
Usage/ApplicationIndustrial Use
ColorGrey
Packaging TypeDrum
Shelf Life24 Months

Anti Magnetic Coating — a specialized protective layer designed to shield sensitive equipment from magnetic interference.

Reduces the impact of external magnetic fields on devices

Enhances accuracy and stability of precision instruments

Suitable for scientific, industrial, and electronic applications

Provides a smooth, durable, and long-lasting finish

Can be applied to metals, machinery, and enclosures

Resistant to wear, moisture, and environmental damage

Helps extend the lifespan of protected equipment

Easy to apply using spray, brush, or dip methods

Request
Callback
Yes! I am Interested

Rudra Fire Barrier

Rudra Fire Barrier
  • Rudra Fire Barrier
  • Rudra Fire Barrier
  • Rudra Fire Barrier
  • Rudra Fire Barrier
Get Best Quote
Approx. Price: Rs 145 / PieceGet Latest Price

Product Details:

Minimum Order Quantity20 Piece
MaterialGOVERMENT LAB TASTED CERTIFICATE
Country of OriginMade in India

Fire seal mortar, also known as firestop mortar or fire barrier mortar, is a type of fire-resistant material used to seal openings and joints in walls, floors, and ceilings to prevent the spread of fire, smoke, and toxic gases. Here is detailed information about fire seal mortar:

Composition

Fire seal mortar typically consists of the following components:

  • Portland Cement: Provides strength and durability.
  • Lightweight Aggregates: Helps in maintaining the mortar's lightweight properties.
  • Fire Retardant Additives: Enhance the fire-resistant properties.
  • Fibers: Improve tensile strength and crack resistance.
Applications

Fire seal mortar is used in various applications, including:

  • Penetration Seals: Around pipes, cables, ducts, and conduits that pass through fire-rated walls and floors.
  • Construction Joints: In expansion joints, control joints, and other gaps in fire-rated assemblies.
  • Cable Trays and Conduits: To seal around electrical and communication cables.
Properties

Key properties of fire seal mortar include:

  • Fire Resistance: Can withstand high temperatures and prevent the passage of flames, smoke, and gases for a specified period, typically measured in hours (e.g., 1-hour, 2-hour fire ratings).
  • Adhesion: Adheres well to various construction materials such as concrete, brick, steel, and plastic.
  • Durability: Maintains integrity and effectiveness over time.
  • Ease of Application: Can be easily mixed and applied, either manually or using mechanical means.
  • Acoustic Insulation: Provides some level of soundproofing, reducing noise transmission through sealed openings.
Installation

The installation process typically involves the following steps:

  1. Preparation: Clean the surfaces around the opening to remove dust, debris, and any loose materials.
  2. Mixing: Combine the dry mortar mix with water according to the manufacturer's instructions to achieve the desired consistency.
  3. Application: Apply the mortar using a trowel or other appropriate tools to fill the opening or joint completely.
  4. Curing: Allow the mortar to cure as per the recommended time, which ensures it achieves full strength and fire-resistant properties.
Standards and Certifications

Fire seal mortar must comply with various building codes and standards, which may include:

  • ASTM E814 / UL 1479: Standard test methods for fire tests of penetration firestop systems.
  • EN 1366-3: European standard for fire resistance tests for service installations - penetration seals.
  • BS 476: British standard for fire tests on building materials and structures.
Maintenance

Regular inspections and maintenance are crucial to ensure the effectiveness of fire seal mortar. Over time, it may be necessary to repair or replace mortar that has been damaged or degraded.

Request
Callback


Additional Information:

  • Item Code: RP-103..
  • Production Capacity: 20000 KG
  • Delivery Time: 3 DAYS
  • Packaging Details: 20 KG BAG
Yes! I am Interested

Fire Protective Coatings

Fire Protective Coatings
    Get Best Quote
    Approx. Price: Rs 550 / KgGet Latest Price

    Product Details:

    Coating typeFire retardant

    Request
    Callback
    Yes! I am Interested
    X

    Product Videos

    Explore More Products

    View All Products
    Tell Us What Are You Looking For ?




    Reach Us
    Bhagirath Sinh Chauhan (Director)
    Rudra Enterprise
    Ground Floor, Plot No.61, Pandol Ind Soc, Katargam, Ved Road, Opp. Keshavpark Society
    Surat - 395004, Gujarat, India
    Get Directions

    Call Us


    Send E-mail